EXPERIMENTAL STUDY OF REFRIGERANT REPLACEMENT FROM R-22 TO R-290 HYDROCARBON IN DOMESTIC AC
Abstract
Keywords
Full Text:
69-79 (PDF)References
Abas, N., Kalair, A. R., Khan, N., Haider, A., Saleem, Z., & Saleem, M. S. (2018). Natural and synthetic refrigerants, global warming: A review. Renewable and Sustainable Energy Reviews, 90(February), 557–569. https://doi.org/10.1016/j.rser.2018.03.099
Joni Santoso, S. (2018). Analisa Perbandingan Konsumsi Listrik pada AC Split Berbahan Pendingin R-22 dengan AC Split Berbahan Pendingin MC-22. Angewandte Chemie International Edition, 6(11), 951–952., 12(3), 1–8. Retrieved from https://doi.org/10.1016/j.phrs.2020.104743%0Ahttps://doi.org/10.1057/s41267-019-00222-y
Joudi, K. A., & Al-Amir, Q. R. (2014). Experimental Assessment of residential split type air-conditioning systems using alternative refrigerants to R-22 at high ambient temperatures. Energy Conversion and Management, 86, 496–506. https://doi.org/10.1016/j.enconman.2014.05.036
Moran, M. J. (2018). Engineering thermodynamics. In Mechatronic Systems, Sensors, and Actuators: Fundamentals and Modeling.
Pujianto, M. E., Tamtomo Kiono, B. F., & Tony Suryo, M. S. K. (2019). Experimental study on the performance of a R-22 freezer retrofitted with R-290. Materials Today: Proceedings, 13, 160–164. https://doi.org/10.1016/j.matpr.2019.03.207
Urip Prayogi, & Rohman Sugiono. (2022). 494526-Analisa-Perbandingan-Global-Warming-Pote-C1Adb12F. Jurnal Teknik Mesin: Vol. 11, No. 1, 11(ANALISIS GLOBAL WARMING POTENTIAL (GWP) DAN OZONE DEPLETION POTENTIAL (ODP), PADA REFRIGERAN R32, R290, R407C, R410A, SEBAGAI PENGGANTI R22), 15–18.
Wabang, J. A., Hattu, E. P. D., & Abanat, J. D. J. (2021). Performance Analysis of Air Conditioning System Using Freon R22 and Musicool ( Mc 22 ) Based on Speed of Variation of Air Conditioning Condensers. 208(ICIST 2020), 283–286.
Widyastuti, Putra, A. B. K., Hantoro, R., Novianarenti, E., & Safitra, A. G. (2014). Improved energy saving for R22 building air conditioning retrofitted with hydrocarbon refrigerant, Study case: Civil engineering department of ITS. Applied Mechanics and Materials, 493(January), 281–286. https://doi.org/10.4028/www.scientific.net/AMM.493.281
DOI: https://doi.org/10.21831/dinamika.v8i1.65204
Refbacks
- There are currently no refbacks.
Copyright (c) 2023 Jurnal Dinamika Vokasional Teknik Mesin

This work is licensed under a Creative Commons Attribution 4.0 International License.

Jurnal Dinamika Vokasional Teknik Mesin by http://journal.uny.ac.id/index.php/dynamika was distributed under a Creative Commons Attribution 4.0 International License.
Â
View My Stats